using ICSSoft.Common; using ICSSoft.Entity; using Newtonsoft.Json; using Newtonsoft.Json.Linq; using System; using System.Collections.Generic; using System.Data; using System.Data.SqlClient; using System.Linq; using System.Net.Http; using System.Text; using System.Threading.Tasks; namespace ICSSoft.DataProject { /// /// 使用中 /// 生产模块 /// public class ICSManufactureService { private static log4net.ILog log = log4net.LogManager.GetLogger(System.Reflection.MethodBase.GetCurrentMethod().DeclaringType); #region 生产发料 /// /// 生产发料 /// /// /// /// /// /// public static void MOIssueDoc(string TransCode, string TransSequence, string Quantity, string WorkPoint, SqlCommand cmd, Dictionary language) { try { string sql = @"DECLARE @Status VARCHAR(10) SELECT @Status=b.ERPStatus FROM ICSMOPick a INNER JOIN ICSMO b ON a.MODetailID=b.MODetailID AND a.WorkPoint=b.WorkPoint WHERE b.MOCode='{0}' AND b.Sequence+'~'+a.Sequence='{3}' AND a.WorkPoint='{1}' IF (@Status IS NULL) BEGIN RAISERROR('" + language.GetNameByCode("WMSAPIInfo125") + @"',16,1); RETURN END ELSE IF (@Status!='2') BEGIN RAISERROR('" + language.GetNameByCode("WMSAPIInfo126") + @"',16,1); RETURN END UPDATE a SET IssueQuantity=ISNULL(IssueQuantity,0)+'{2}' FROM ICSMOPick a INNER JOIN ICSMO b ON a.MODetailID=b.MODetailID AND a.WorkPoint=b.WorkPoint WHERE b.MOCode='{0}' AND b.Sequence+'~'+a.Sequence='{3}' AND a.WorkPoint='{1}' IF EXISTS(SELECT a.ID FROM ICSMOPick a INNER JOIN ICSMO b ON a.MODetailID=b.MODetailID AND a.WorkPoint=b.WorkPoint WHERE b.MOCode='{0}' AND b.Sequence+'~'+a.Sequence='{3}' and a.WorkPoint='{1}' AND a.Quantity /// 生产发料接口 /// /// /// /// public static void MOIssueDocERP(string TransType, string Identification, SqlCommand cmd, Dictionary language) { try { #region ERP string sql = @"SELECT y.DepCode+a.FromWarehouseCode+y.MOCode+a.MUSER AS Costre,y.DepCode,a.FromWarehouseCode AS WarehouseCode,y.MOCode,a.MUSER,ROW_NUMBER() OVER (ORDER BY y.DepCode,a.FromWarehouseCode,y.MOCode,x.PickID,a.InvCode) AS Sequence, a.InvCode,SUM(a.Quantity) AS Quantity,SUM(a.Quantity*(lot.Amount/lot.Quantity)) AS Amount,x.PickID,con.Enable AS UpdateTodoQuantity ,a.WorkPoint,ISNULL(ext.ProjectCode, '') AS ProjectCode,CASE WHEN (invBat.BatchEnable IS NULL AND ISNULL(inv.BatchEnable, '0')='1') OR ISNULL(invBat.BatchEnable, '0')='1' THEN ISNULL(ext.BatchCode, '') ELSE '' END AS BatchCode,ISNULL(ext.Version, '') AS Version,ISNULL(ext.Brand, '') AS Brand, ISNULL(ext.cFree1, '') AS cFree1,ISNULL(ext.cFree2, '') AS cFree2,ISNULL(ext.cFree3, '') AS cFree3,ISNULL(ext.cFree4, '') AS cFree4,ISNULL(ext.cFree5, '') AS cFree5,ISNULL(ext.cFree6, '') AS cFree6,ISNULL(ext.cFree7, '') AS cFree7,ISNULL(ext.cFree8, '') AS cFree8,ISNULL(ext.cFree9, '') AS cFree9,ISNULL(ext.cFree10, '') AS cFree10,conv.Enable AS CompleteVerification INTO #TempERP FROM ICSWareHouseLotInfoLog a INNER JOIN ICSInventoryLot lot ON a.LotNo=lot.LotNo AND a.WorkPoint=lot.WorkPoint INNER JOIN ICSExtension ext ON lot.ExtensionID=ext.ID AND lot.WorkPoint=ext.WorkPoint INNER JOIN ICSInventory inv ON a.InvCode=inv.InvCode AND a.WorkPoint=inv.WorkPoint LEFT JOIN ICSInventoryBatchEnable invBat ON a.InvCode=invBat.InvCode AND a.FromWarehouseCode=invBat.WHCode AND a.WorkPoint=invBat.WorkPoint INNER JOIN ICSMO y ON a.TransCode=y.MOCode AND a.WorkPoint=y.WorkPoint INNER JOIN ICSMOPick x ON x.MODetailID=y.MODetailID AND a.TransSequence=y.Sequence+'~'+x.Sequence AND x.WorkPoint=y.WorkPoint INNER JOIN ICSConfiguration con ON con.Code='Stock002' AND a.WorkPoint=con.WorkPoint INNER JOIN ICSConfiguration conv ON conv.Code='CompleteVerification' AND a.WorkPoint=conv.WorkPoint WHERE a.Identification='{0}' AND ERPUpload='0' AND a.BusinessCode = '13' GROUP BY y.DepCode,a.FromWarehouseCode,y.MOCode,a.MUSER,a.InvCode,lot.Amount,lot.Quantity,x.PickID,x.MODetailID,con.Enable,conv.Enable ,a.WorkPoint,ISNULL(ext.ProjectCode, ''),CASE WHEN (invBat.BatchEnable IS NULL AND ISNULL(inv.BatchEnable, '0')='1') OR ISNULL(invBat.BatchEnable, '0')='1' THEN ISNULL(ext.BatchCode, '') ELSE '' END,ISNULL(ext.Version, ''),ISNULL(ext.Brand, ''), ISNULL(ext.cFree1, ''),ISNULL(ext.cFree2, ''),ISNULL(ext.cFree3, ''),ISNULL(ext.cFree4, ''),ISNULL(ext.cFree5, ''),ISNULL(ext.cFree6, ''),ISNULL(ext.cFree7, ''),ISNULL(ext.cFree8, ''),ISNULL(ext.cFree9, ''),ISNULL(ext.cFree10, '') SELECT DISTINCT Costre,WorkPoint,DepCode,WarehouseCode AS WHCode,'生产订单' AS SourceType,MOCode AS SourceCode,MUSER AS [User],SYSDATETIME() AS MTime,UpdateTodoQuantity,CompleteVerification FROM #TempERP SELECT Costre,Sequence,InvCode,Quantity,Amount,PickID AS SourceDetailID,ProjectCode,BatchCode,Version,Brand,cFree1,cFree2,cFree3,cFree4,cFree5,cFree6,cFree7,cFree8,cFree9,cFree10 FROM #TempERP DROP TABLE #TempERP"; sql = string.Format(sql, Identification); DataSet ds = DBHelper.SQlReturnDataSet(sql, cmd); string Inputstr = DataToJsonHelper.DataSetToJson(ds, "details", "Costre"); string resultStr = HTTPHelper.HttpPost(TransType, ERPUrl.MOIssueDocURL, Inputstr); Result result = new Result(); result = JsonConvert.DeserializeObject(resultStr); if (result.Success) { try { JArray res = (JArray)JsonConvert.DeserializeObject(result.Data.ToString()); foreach (var item in res) { JObject jo = (JObject)item; JArray resdetail = (JArray)JsonConvert.DeserializeObject(jo["details"].ToString()); foreach (var detail in resdetail) { JObject det = (JObject)detail; ICSWareHouseLotInfoService.WareHouseLotInfoLogUpdate(TransType, det["SourceDetailID"].ToString(), Identification, jo["ID"].ToString(), det["DetailID"].ToString(), jo["IssueCode"].ToString(), det["Sequence"].ToString(), cmd, language); } } } catch (Exception ex) { log.Debug(ex.ToString()); log.Debug(resultStr); } } else { throw new Exception(language.GetNameByCode("WMSAPIInfo080") + result.Message); } #endregion } catch (Exception) { throw; } } #endregion #region 领料申请单生产发料 /// /// 领料申请单生产发料 /// /// /// /// /// /// public static void MOApply(string TransCode, string TransSequence, string Quantity, string WorkPoint, SqlCommand cmd, Dictionary language) { try { string sql = @"DECLARE @Status VARCHAR(10) SELECT @Status=a.Status FROM ICSMOApply a WHERE a.ApplyCode='{0}' AND a.Sequence='{3}' AND a.WorkPoint='{1}' IF (@Status IS NULL) BEGIN RAISERROR('" + language.GetNameByCode("WMSAPIInfo128") + @"',16,1); RETURN END ELSE IF (@Status!='2') BEGIN RAISERROR('" + language.GetNameByCode("WMSAPIInfo129") + @"',16,1); RETURN END UPDATE a SET IssueQuantity=ISNULL(IssueQuantity,0)+'{2}' FROM ICSMOApply a WHERE a.ApplyCode='{0}' AND a.Sequence='{3}' AND a.WorkPoint='{1}' IF EXISTS(SELECT a.ID FROM ICSMOApply a WHERE a.ApplyCode='{0}' AND a.Sequence='{3}' and a.WorkPoint='{1}' AND a.Quantity /// 领料申请单生产发料接口 /// /// /// /// public static void MOApplyERP(string TransType, string Identification, SqlCommand cmd, Dictionary language) { try { #region ERP string sql = @"SELECT a.FromWarehouseCode+b.ApplyCode+a.MUSER AS Costre,a.FromWarehouseCode AS WarehouseCode,b.ApplyCode,a.MUSER,ROW_NUMBER() OVER (ORDER BY a.FromWarehouseCode,b.ApplyCode,b.ApplyDetailID,a.InvCode) AS Sequence, a.InvCode,SUM(a.Quantity) AS Quantity,SUM(a.Quantity*(lot.Amount/lot.Quantity)) AS Amount,b.ApplyDetailID,con.Enable AS UpdateTodoQuantity ,a.WorkPoint,ISNULL(ext.ProjectCode, '') AS ProjectCode,CASE WHEN (invBat.BatchEnable IS NULL AND ISNULL(inv.BatchEnable, '0')='1') OR ISNULL(invBat.BatchEnable, '0')='1' THEN ISNULL(ext.BatchCode, '') ELSE '' END AS BatchCode,ISNULL(ext.Version, '') AS Version,ISNULL(ext.Brand, '') AS Brand, ISNULL(ext.cFree1, '') AS cFree1,ISNULL(ext.cFree2, '') AS cFree2,ISNULL(ext.cFree3, '') AS cFree3,ISNULL(ext.cFree4, '') AS cFree4,ISNULL(ext.cFree5, '') AS cFree5,ISNULL(ext.cFree6, '') AS cFree6,ISNULL(ext.cFree7, '') AS cFree7,ISNULL(ext.cFree8, '') AS cFree8,ISNULL(ext.cFree9, '') AS cFree9,ISNULL(ext.cFree10, '') AS cFree10,conv.Enable AS CompleteVerification INTO #TempERP FROM ICSWareHouseLotInfoLog a INNER JOIN ICSInventoryLot lot ON a.LotNo=lot.LotNo AND a.WorkPoint=lot.WorkPoint INNER JOIN ICSExtension ext ON lot.ExtensionID=ext.ID AND lot.WorkPoint=ext.WorkPoint INNER JOIN ICSInventory inv ON a.InvCode=inv.InvCode AND a.WorkPoint=inv.WorkPoint LEFT JOIN ICSInventoryBatchEnable invBat ON a.InvCode=invBat.InvCode AND a.FromWarehouseCode=invBat.WHCode AND a.WorkPoint=invBat.WorkPoint INNER JOIN ICSMOApply b ON a.TransCode=b.ApplyCode AND a.TransSequence=b.Sequence AND a.WorkPoint=b.WorkPoint INNER JOIN ICSConfiguration con ON con.Code='Stock002' AND a.WorkPoint=con.WorkPoint INNER JOIN ICSConfiguration conv ON conv.Code='CompleteVerification' AND a.WorkPoint=conv.WorkPoint WHERE a.Identification='{0}' AND ERPUpload='0' AND a.BusinessCode = '14' GROUP BY a.FromWarehouseCode,b.ApplyCode,a.MUSER,a.InvCode,lot.Amount,lot.Quantity,b.ApplyDetailID,con.Enable,conv.Enable ,a.WorkPoint,ISNULL(ext.ProjectCode, ''),CASE WHEN (invBat.BatchEnable IS NULL AND ISNULL(inv.BatchEnable, '0')='1') OR ISNULL(invBat.BatchEnable, '0')='1' THEN ISNULL(ext.BatchCode, '') ELSE '' END,ISNULL(ext.Version, ''),ISNULL(ext.Brand, ''), ISNULL(ext.cFree1, ''),ISNULL(ext.cFree2, ''),ISNULL(ext.cFree3, ''),ISNULL(ext.cFree4, ''),ISNULL(ext.cFree5, ''),ISNULL(ext.cFree6, ''),ISNULL(ext.cFree7, ''),ISNULL(ext.cFree8, ''),ISNULL(ext.cFree9, ''),ISNULL(ext.cFree10, '') SELECT DISTINCT Costre,WorkPoint,'' AS DepCode,WarehouseCode AS WHCode,'领料申请单' AS SourceType,ApplyCode AS SourceCode,MUSER AS [User],SYSDATETIME() AS MTime,UpdateTodoQuantity,CompleteVerification FROM #TempERP SELECT Costre,Sequence,InvCode,Quantity,Amount,ApplyDetailID AS SourceDetailID,ProjectCode,BatchCode,Version,Brand,cFree1,cFree2,cFree3,cFree4,cFree5,cFree6,cFree7,cFree8,cFree9,cFree10 FROM #TempERP DROP TABLE #TempERP"; sql = string.Format(sql, Identification); DataSet ds = DBHelper.SQlReturnDataSet(sql, cmd); string Inputstr = DataToJsonHelper.DataSetToJson(ds, "details", "Costre"); string resultStr = HTTPHelper.HttpPost(TransType, ERPUrl.MOApplyURL, Inputstr); Result result = new Result(); result = JsonConvert.DeserializeObject(resultStr); if (result.Success) { try { JArray res = (JArray)JsonConvert.DeserializeObject(result.Data.ToString()); foreach (var item in res) { JObject jo = (JObject)item; JArray resdetail = (JArray)JsonConvert.DeserializeObject(jo["details"].ToString()); foreach (var detail in resdetail) { JObject det = (JObject)detail; ICSWareHouseLotInfoService.WareHouseLotInfoLogUpdate(TransType, det["SourceDetailID"].ToString(), Identification, jo["ID"].ToString(), det["DetailID"].ToString(), jo["IssueCode"].ToString(), det["Sequence"].ToString(), cmd, language); } } } catch (Exception ex) { log.Debug(ex.ToString()); log.Debug(resultStr); } } else { throw new Exception(language.GetNameByCode("WMSAPIInfo080") + result.Message); } #endregion } catch (Exception) { throw; } } #endregion #region 材料出库单生产发料 /// /// 材料出库单生产发料 /// /// /// /// /// /// public static void MOIssue(string TransCode, string TransSequence, string Quantity, string WorkPoint, SqlCommand cmd, Dictionary language) { try { string sql = @"DECLARE @Status VARCHAR(10) SELECT @Status=a.Status FROM ICSMOIssue a WHERE a.IssueCode='{0}' AND a.Sequence='{3}' AND a.WorkPoint='{1}' IF (@Status IS NULL) BEGIN RAISERROR('" + language.GetNameByCode("WMSAPIInfo131") + @"',16,1); RETURN END ELSE IF (@Status!='1') BEGIN RAISERROR('" + language.GetNameByCode("WMSAPIInfo132") + @"',16,1); RETURN END UPDATE a SET IssueQuantity=ISNULL(IssueQuantity,0)+'{2}' FROM ICSMOIssue a WHERE a.IssueCode='{0}' AND a.Sequence='{3}' AND a.WorkPoint='{1}' IF EXISTS(SELECT a.ID FROM ICSMOIssue a WHERE a.IssueCode='{0}' AND a.Sequence='{3}' and a.WorkPoint='{1}' AND a.Quantity /// 材料出库单生产发料接口 /// /// /// /// public static void MOIssueERP(string TransType, string Identification, SqlCommand cmd, Dictionary language) { try { #region ERP开立状态单据审核 string sql = @"IF EXISTS(SELECT b.ID FROM ICSWareHouseLotInfoLog a INNER JOIN ICSMOIssue b ON a.TransCode=b.IssueCode AND a.TransSequence=b.Sequence AND a.WorkPoint=b.WorkPoint WHERE a.Identification='{0}' AND b.Quantity!=b.IssueQuantity) BEGIN RAISERROR('" + language.GetNameByCode("WMSAPIInfo094") + @"',16,1); RETURN END SELECT b.IssueID AS ID,a.MUSER AS [User],SYSDATETIME() AS MTime,con.Enable AS UpdateTodoQuantity ,conStock.Enable AS UpdateStock,a.WorkPoint FROM ICSWareHouseLotInfoLog a INNER JOIN ICSMOIssue b ON a.TransCode=b.IssueCode AND a.TransSequence=b.Sequence AND a.WorkPoint=b.WorkPoint INNER JOIN ICSConfiguration con ON con.Code='Stock002' AND a.WorkPoint=con.WorkPoint INNER JOIN ICSConfiguration conStock ON conStock.Code='UpdateStock002' AND a.WorkPoint=conStock.WorkPoint WHERE a.Identification='{0}' AND ERPUpload='0' AND a.BusinessCode = '15' GROUP BY b.IssueID,a.MUSER,con.Enable ,conStock.Enable,a.WorkPoint"; sql = string.Format(sql, Identification); DataTable dt = DBHelper.SQlReturnData(sql, cmd); string Inputstr = JsonConvert.SerializeObject(dt); string resultStr = HTTPHelper.HttpPost(TransType, ERPUrl.MOIssueURL, Inputstr); Result result = new Result(); result = JsonConvert.DeserializeObject(resultStr); if (result.Success) { try { foreach (DataRow dr in dt.Rows) { ICSWareHouseLotInfoService.WareHouseLotInfoLogUpdate(TransType, dr["ID"].ToString(), Identification, "", "", "", "", cmd, language); } } catch (Exception ex) { log.Debug(ex.ToString()); log.Debug(resultStr); } } else { throw new Exception(language.GetNameByCode("WMSAPIInfo080") + result.Message); } #endregion } catch (Exception) { throw; } } #endregion #region 生产退料 /// /// 生产退料 /// /// /// /// /// /// public static void MOIssueDocNegative(string TransType, string LogID, string LotNo, string Quantity, string WorkPoint, SqlCommand cmd, Dictionary language) { try { string table = ""; string sql = ""; if (string.IsNullOrWhiteSpace(LogID)) { string type = ""; if (TransType == TransTypeEnum.MOIssueDocNegative.GetDescription()) { table = "INNER JOIN ICSMOPick e ON c.SourceDetailID=e.PickID AND c.WorkPoint=e.WorkPoint"; type = "1"; } else if (TransType == TransTypeEnum.MOIssueDocNegativeApply.GetDescription()) { table = "INNER JOIN ICSMOApply e ON c.SourceDetailID=e.ApplyDetailID AND c.WorkPoint=e.WorkPoint"; type = "2"; } else if (TransType == TransTypeEnum.MOIssueDocNegativeIssue.GetDescription()) { table = "INNER JOIN ICSMOIssue e ON c.SourceDetailID=e.IssueDetailID AND c.WorkPoint=e.WorkPoint"; type = "3"; } else { throw new Exception(language.GetNameByCode("WMSAPIInfo003"));//"类型不符!"); } #region 新条码 sql = @"UPDATE c SET IssueNegQuantity=ISNULL(IssueNegQuantity,0)+'{2}' FROM ICSInventoryLot a INNER JOIN ICSInventoryLotDetail b ON a.LotNo=b.LotNo AND a.WorkPoint=b.WorkPoint INNER JOIN ICSMOApplyNegDetail c ON b.TransCode=c.ApplyNegCode AND b.TransSequence=c.Sequence AND b.WorkPoint=c.WorkPoint INNER JOIN ICSMOApplyNeg d ON c.ApplyNegCode=d.ApplyNegCode AND c.WorkPoint=d.WorkPoint WHERE a.LotNo='{0}' AND a.WorkPoint='{1}' AND d.Type='{4}' IF EXISTS(SELECT a.LotNo FROM ICSInventoryLot a INNER JOIN ICSInventoryLotDetail b ON a.LotNo=b.LotNo AND a.WorkPoint=b.WorkPoint INNER JOIN ICSMOApplyNegDetail c ON b.TransCode=c.ApplyNegCode AND b.TransSequence=c.Sequence AND b.WorkPoint=c.WorkPoint INNER JOIN ICSMOApplyNeg d ON c.ApplyNegCode=d.ApplyNegCode AND c.WorkPoint=d.WorkPoint WHERE a.LotNo='{0}' AND a.WorkPoint='{1}' AND d.Type='{4}' AND c.Quantity /// 生产退料接口 /// /// /// /// public static void MOIssueDocNegativeERP(string TransType, string Identification, SqlCommand cmd, Dictionary language) { try { #region ERP string sql = string.Empty; if (TransType == TransTypeEnum.MOIssueDocNegative.GetDescription()) { sql = @"SELECT y.DepCode+a.ToWarehouseCode+y.MOCode+a.MUSER AS Costre,y.DepCode,a.ToWarehouseCode AS WarehouseCode,y.MOCode,a.MUSER,ROW_NUMBER() OVER (ORDER BY y.DepCode,a.ToWarehouseCode,y.MOCode,x.PickID,a.InvCode) AS Sequence, a.InvCode,SUM(a.Quantity) AS Quantity,SUM(a.Quantity*(lot.Amount/lot.Quantity)) AS Amount,x.PickID AS SourceDetailID,con.Enable AS UpdateTodoQuantity ,a.WorkPoint,ISNULL(ext.ProjectCode, '') AS ProjectCode,CASE WHEN (invBat.BatchEnable IS NULL AND ISNULL(inv.BatchEnable, '0')='1') OR ISNULL(invBat.BatchEnable, '0')='1' THEN ISNULL(ext.BatchCode, '') ELSE '' END AS BatchCode,ISNULL(ext.Version, '') AS Version,ISNULL(ext.Brand, '') AS Brand, ISNULL(ext.cFree1, '') AS cFree1,ISNULL(ext.cFree2, '') AS cFree2,ISNULL(ext.cFree3, '') AS cFree3,ISNULL(ext.cFree4, '') AS cFree4,ISNULL(ext.cFree5, '') AS cFree5,ISNULL(ext.cFree6, '') AS cFree6,ISNULL(ext.cFree7, '') AS cFree7,ISNULL(ext.cFree8, '') AS cFree8,ISNULL(ext.cFree9, '') AS cFree9,ISNULL(ext.cFree10, '') AS cFree10 INTO #TempERP FROM ICSWareHouseLotInfoLog a INNER JOIN ICSInventoryLot lot ON a.LotNo=lot.LotNo AND a.WorkPoint=lot.WorkPoint INNER JOIN ICSExtension ext ON lot.ExtensionID=ext.ID AND lot.WorkPoint=ext.WorkPoint INNER JOIN ICSInventory inv ON a.InvCode=inv.InvCode AND a.WorkPoint=inv.WorkPoint LEFT JOIN ICSInventoryBatchEnable invBat ON a.InvCode=invBat.InvCode AND a.ToWarehouseCode=invBat.WHCode AND a.WorkPoint=invBat.WorkPoint INNER JOIN ICSInventoryLotDetail b ON a.LotNo=b.LotNo AND a.WorkPoint=b.WorkPoint INNER JOIN ICSMOApplyNegDetail c ON b.TransCode=c.ApplyNegCode AND b.TransSequence=c.Sequence AND b.WorkPoint=c.WorkPoint INNER JOIN ICSMOPick x ON c.SourceDetailID=x.PickID AND c.WorkPoint=x.WorkPoint INNER JOIN ICSMO y ON x.MODetailID=y.MODetailID AND x.WorkPoint=y.WorkPoint INNER JOIN ICSConfiguration con ON con.Code='Stock001' AND a.WorkPoint=con.WorkPoint WHERE a.Identification='{0}' AND a.ERPUpload='0' AND ISNULL(a.LogID, '')='' GROUP BY y.DepCode,a.ToWarehouseCode,y.MOCode,a.MUSER,a.InvCode,lot.Amount,lot.Quantity,x.PickID,x.MODetailID,con.Enable ,a.WorkPoint,ISNULL(ext.ProjectCode, ''),CASE WHEN (invBat.BatchEnable IS NULL AND ISNULL(inv.BatchEnable, '0')='1') OR ISNULL(invBat.BatchEnable, '0')='1' THEN ISNULL(ext.BatchCode, '') ELSE '' END,ISNULL(ext.Version, ''),ISNULL(ext.Brand, ''), ISNULL(ext.cFree1, ''),ISNULL(ext.cFree2, ''),ISNULL(ext.cFree3, ''),ISNULL(ext.cFree4, ''),ISNULL(ext.cFree5, ''),ISNULL(ext.cFree6, ''),ISNULL(ext.cFree7, ''),ISNULL(ext.cFree8, ''),ISNULL(ext.cFree9, ''),ISNULL(ext.cFree10, '') UNION ALL SELECT y.DepCode+a.ToWarehouseCode+y.MOCode+a.MUSER AS Costre,y.DepCode,a.ToWarehouseCode AS WarehouseCode,y.MOCode,a.MUSER,ROW_NUMBER() OVER (ORDER BY y.DepCode,a.ToWarehouseCode,y.MOCode,x.PickID,a.InvCode) AS Sequence, a.InvCode,SUM(a.Quantity) AS Quantity,0 AS Amount,x.PickID AS SourceDetailID,con.Enable AS UpdateTodoQuantity ,a.WorkPoint,ISNULL(ext.ProjectCode, '') AS ProjectCode,CASE WHEN (invBat.BatchEnable IS NULL AND ISNULL(inv.BatchEnable, '0')='1') OR ISNULL(invBat.BatchEnable, '0')='1' THEN ISNULL(ext.BatchCode, '') ELSE '' END AS BatchCode,ISNULL(ext.Version, '') AS Version,ISNULL(ext.Brand, '') AS Brand, ISNULL(ext.cFree1, '') AS cFree1,ISNULL(ext.cFree2, '') AS cFree2,ISNULL(ext.cFree3, '') AS cFree3,ISNULL(ext.cFree4, '') AS cFree4,ISNULL(ext.cFree5, '') AS cFree5,ISNULL(ext.cFree6, '') AS cFree6,ISNULL(ext.cFree7, '') AS cFree7,ISNULL(ext.cFree8, '') AS cFree8,ISNULL(ext.cFree9, '') AS cFree9,ISNULL(ext.cFree10, '') AS cFree10 FROM ICSWareHouseLotInfoLog a INNER JOIN ICSInventoryLot lot ON a.LotNo=lot.LotNo AND a.WorkPoint=lot.WorkPoint INNER JOIN ICSExtension ext ON lot.ExtensionID=ext.ID AND lot.WorkPoint=ext.WorkPoint INNER JOIN ICSInventory inv ON a.InvCode=inv.InvCode AND a.WorkPoint=inv.WorkPoint LEFT JOIN ICSInventoryBatchEnable invBat ON a.InvCode=invBat.InvCode AND a.ToWarehouseCode=invBat.WHCode AND a.WorkPoint=invBat.WorkPoint INNER JOIN ICSWareHouseLotInfoLog b ON a.LogID=b.ID AND a.WorkPoint=b.WorkPoint INNER JOIN ICSMO y ON b.TransCode=y.MOCode AND b.WorkPoint=y.WorkPoint INNER JOIN ICSMOPick x ON x.MODetailID=y.MODetailID AND x.WorkPoint=y.WorkPoint AND b.TransSequence = y.Sequence + '~' + x.Sequence INNER JOIN ICSConfiguration con ON con.Code='Stock001' AND a.WorkPoint=con.WorkPoint WHERE a.Identification='{0}' AND a.ERPUpload='0' AND ISNULL(a.LogID, '')<>'' GROUP BY y.DepCode,a.ToWarehouseCode,y.MOCode,a.MUSER,lot.Amount,lot.Quantity,a.InvCode,x.PickID,x.MODetailID,con.Enable ,a.WorkPoint,ISNULL(ext.ProjectCode, ''),CASE WHEN (invBat.BatchEnable IS NULL AND ISNULL(inv.BatchEnable, '0')='1') OR ISNULL(invBat.BatchEnable, '0')='1' THEN ISNULL(ext.BatchCode, '') ELSE '' END,ISNULL(ext.Version, ''),ISNULL(ext.Brand, ''), ISNULL(ext.cFree1, ''),ISNULL(ext.cFree2, ''),ISNULL(ext.cFree3, ''),ISNULL(ext.cFree4, ''),ISNULL(ext.cFree5, ''),ISNULL(ext.cFree6, ''),ISNULL(ext.cFree7, ''),ISNULL(ext.cFree8, ''),ISNULL(ext.cFree9, ''),ISNULL(ext.cFree10, '') SELECT DISTINCT Costre,WorkPoint,DepCode,WarehouseCode AS WHCode,'生产订单' AS SourceType,MOCode AS SourceCode,MUSER AS [User],SYSDATETIME() AS MTime,UpdateTodoQuantity FROM #TempERP SELECT Costre,Sequence,InvCode,Quantity,Amount,SourceDetailID,ProjectCode,BatchCode,Version,Brand,cFree1,cFree2,cFree3,cFree4,cFree5,cFree6,cFree7,cFree8,cFree9,cFree10 FROM #TempERP DROP TABLE #TempERP"; } else if (TransType == TransTypeEnum.MOIssueDocNegativeApply.GetDescription()) { sql = @"SELECT a.ToWarehouseCode+z.ApplyCode+a.MUSER AS Costre,'' AS DepCode,a.ToWarehouseCode AS WarehouseCode,z.ApplyCode,a.MUSER,ROW_NUMBER() OVER (ORDER BY a.ToWarehouseCode,z.ApplyCode,z.ApplyDetailID,a.InvCode) AS Sequence, a.InvCode,SUM(a.Quantity) AS Quantity,0 AS Amount,z.ApplyDetailID AS SourceDetailID,con.Enable AS UpdateTodoQuantity ,a.WorkPoint,ISNULL(ext.ProjectCode, '') AS ProjectCode,CASE WHEN (invBat.BatchEnable IS NULL AND ISNULL(inv.BatchEnable, '0')='1') OR ISNULL(invBat.BatchEnable, '0')='1' THEN ISNULL(ext.BatchCode, '') ELSE '' END AS BatchCode,ISNULL(ext.Version, '') AS Version,ISNULL(ext.Brand, '') AS Brand, ISNULL(ext.cFree1, '') AS cFree1,ISNULL(ext.cFree2, '') AS cFree2,ISNULL(ext.cFree3, '') AS cFree3,ISNULL(ext.cFree4, '') AS cFree4,ISNULL(ext.cFree5, '') AS cFree5,ISNULL(ext.cFree6, '') AS cFree6,ISNULL(ext.cFree7, '') AS cFree7,ISNULL(ext.cFree8, '') AS cFree8,ISNULL(ext.cFree9, '') AS cFree9,ISNULL(ext.cFree10, '') AS cFree10 INTO #TempERP FROM ICSWareHouseLotInfoLog a INNER JOIN ICSInventoryLot lot ON a.LotNo=lot.LotNo AND a.WorkPoint=lot.WorkPoint INNER JOIN ICSExtension ext ON lot.ExtensionID=ext.ID AND lot.WorkPoint=ext.WorkPoint INNER JOIN ICSInventory inv ON a.InvCode=inv.InvCode AND a.WorkPoint=inv.WorkPoint LEFT JOIN ICSInventoryBatchEnable invBat ON a.InvCode=invBat.InvCode AND a.ToWarehouseCode=invBat.WHCode AND a.WorkPoint=invBat.WorkPoint INNER JOIN ICSInventoryLotDetail b ON a.LotNo=b.LotNo AND a.WorkPoint=b.WorkPoint INNER JOIN ICSMOApplyNegDetail c ON b.TransCode=c.ApplyNegCode AND b.TransSequence=c.Sequence AND b.WorkPoint=c.WorkPoint INNER JOIN ICSMOApply z ON c.SourceDetailID=z.ApplyDetailID AND c.WorkPoint=z.WorkPoint INNER JOIN ICSConfiguration con ON con.Code='Stock001' AND a.WorkPoint=con.WorkPoint WHERE a.Identification='{0}' AND a.ERPUpload='0' AND ISNULL(a.LogID, '')='' GROUP BY a.ToWarehouseCode,z.ApplyCode,a.MUSER,a.InvCode,z.ApplyDetailID,con.Enable ,a.WorkPoint,ISNULL(ext.ProjectCode, ''),CASE WHEN (invBat.BatchEnable IS NULL AND ISNULL(inv.BatchEnable, '0')='1') OR ISNULL(invBat.BatchEnable, '0')='1' THEN ISNULL(ext.BatchCode, '') ELSE '' END,ISNULL(ext.Version, ''),ISNULL(ext.Brand, ''), ISNULL(ext.cFree1, ''),ISNULL(ext.cFree2, ''),ISNULL(ext.cFree3, ''),ISNULL(ext.cFree4, ''),ISNULL(ext.cFree5, ''),ISNULL(ext.cFree6, ''),ISNULL(ext.cFree7, ''),ISNULL(ext.cFree8, ''),ISNULL(ext.cFree9, ''),ISNULL(ext.cFree10, '') UNION ALL SELECT a.ToWarehouseCode+z.ApplyCode+a.MUSER AS Costre,'' AS DepCode,a.ToWarehouseCode AS WarehouseCode,z.ApplyCode,a.MUSER,ROW_NUMBER() OVER (ORDER BY a.ToWarehouseCode,z.ApplyCode,z.ApplyDetailID,a.InvCode) AS Sequence, a.InvCode,SUM(a.Quantity) AS Quantity,0 AS Amount,z.ApplyDetailID AS SourceDetailID,con.Enable AS UpdateTodoQuantity ,a.WorkPoint,ISNULL(ext.ProjectCode, '') AS ProjectCode,CASE WHEN (invBat.BatchEnable IS NULL AND ISNULL(inv.BatchEnable, '0')='1') OR ISNULL(invBat.BatchEnable, '0')='1' THEN ISNULL(ext.BatchCode, '') ELSE '' END AS BatchCode,ISNULL(ext.Version, '') AS Version,ISNULL(ext.Brand, '') AS Brand, ISNULL(ext.cFree1, '') AS cFree1,ISNULL(ext.cFree2, '') AS cFree2,ISNULL(ext.cFree3, '') AS cFree3,ISNULL(ext.cFree4, '') AS cFree4,ISNULL(ext.cFree5, '') AS cFree5,ISNULL(ext.cFree6, '') AS cFree6,ISNULL(ext.cFree7, '') AS cFree7,ISNULL(ext.cFree8, '') AS cFree8,ISNULL(ext.cFree9, '') AS cFree9,ISNULL(ext.cFree10, '') AS cFree10 FROM ICSWareHouseLotInfoLog a INNER JOIN ICSInventoryLot lot ON a.LotNo=lot.LotNo AND a.WorkPoint=lot.WorkPoint INNER JOIN ICSExtension ext ON lot.ExtensionID=ext.ID AND lot.WorkPoint=ext.WorkPoint INNER JOIN ICSInventory inv ON a.InvCode=inv.InvCode AND a.WorkPoint=inv.WorkPoint LEFT JOIN ICSInventoryBatchEnable invBat ON a.InvCode=invBat.InvCode AND a.ToWarehouseCode=invBat.WHCode AND a.WorkPoint=invBat.WorkPoint INNER JOIN ICSWareHouseLotInfoLog b ON a.LogID=b.ID AND a.WorkPoint=b.WorkPoint INNER JOIN ICSMOApply z ON b.TransCode=z.ApplyCode AND b.TransSequence=z.Sequence AND b.WorkPoint=z.WorkPoint INNER JOIN ICSConfiguration con ON con.Code='Stock001' AND a.WorkPoint=con.WorkPoint WHERE a.Identification='{0}' AND a.ERPUpload='0' AND ISNULL(a.LogID, '')<>'' GROUP BY a.ToWarehouseCode,z.ApplyCode,a.MUSER,a.InvCode,z.ApplyDetailID,con.Enable ,a.WorkPoint,ISNULL(ext.ProjectCode, ''),CASE WHEN (invBat.BatchEnable IS NULL AND ISNULL(inv.BatchEnable, '0')='1') OR ISNULL(invBat.BatchEnable, '0')='1' THEN ISNULL(ext.BatchCode, '') ELSE '' END,ISNULL(ext.Version, ''),ISNULL(ext.Brand, ''), ISNULL(ext.cFree1, ''),ISNULL(ext.cFree2, ''),ISNULL(ext.cFree3, ''),ISNULL(ext.cFree4, ''),ISNULL(ext.cFree5, ''),ISNULL(ext.cFree6, ''),ISNULL(ext.cFree7, ''),ISNULL(ext.cFree8, ''),ISNULL(ext.cFree9, ''),ISNULL(ext.cFree10, '') SELECT DISTINCT Costre,WorkPoint,DepCode,WarehouseCode AS WHCode,'领料申请单' AS SourceType,ApplyCode AS SourceCode,MUSER AS [User],SYSDATETIME() AS MTime,UpdateTodoQuantity FROM #TempERP SELECT Costre,Sequence,InvCode,Quantity,Amount,SourceDetailID,ProjectCode,BatchCode,Version,Brand,cFree1,cFree2,cFree3,cFree4,cFree5,cFree6,cFree7,cFree8,cFree9,cFree10 FROM #TempERP DROP TABLE #TempERP"; } //根据材料出库单查询上游单据,根据上游单据生成红字材料出库 else if (TransType == TransTypeEnum.MOIssueDocNegativeIssue.GetDescription()) { sql = @"SELECT ISNULL(y.DepCode, '')+a.ToWarehouseCode+a.MUSER AS Costre,ISNULL(y.DepCode, '') AS DepCode,a.ToWarehouseCode AS WarehouseCode,CASE WHEN m.ApplyDetailID IS NOT NULL THEN '领料申请单' WHEN m.PickID IS NOT NULL THEN '生产订单' ELSE '' END AS SourceType,ISNULL(z.ApplyCode, y.MOCode) AS MOCode,a.MUSER,ROW_NUMBER() OVER (ORDER BY ISNULL(y.DepCode, ''),a.ToWarehouseCode,ISNULL(z.ApplyCode, y.MOCode),ISNULL(m.ApplyDetailID, m.PickID),a.InvCode) AS Sequence, a.InvCode,SUM(a.Quantity) AS Quantity,0 AS Amount,ISNULL(m.ApplyDetailID, m.PickID) AS SourceDetailID,con.Enable AS UpdateTodoQuantity ,a.WorkPoint,ISNULL(ext.ProjectCode, '') AS ProjectCode,CASE WHEN (invBat.BatchEnable IS NULL AND ISNULL(inv.BatchEnable, '0')='1') OR ISNULL(invBat.BatchEnable, '0')='1' THEN ISNULL(ext.BatchCode, '') ELSE '' END AS BatchCode,ISNULL(ext.Version, '') AS Version,ISNULL(ext.Brand, '') AS Brand, ISNULL(ext.cFree1, '') AS cFree1,ISNULL(ext.cFree2, '') AS cFree2,ISNULL(ext.cFree3, '') AS cFree3,ISNULL(ext.cFree4, '') AS cFree4,ISNULL(ext.cFree5, '') AS cFree5,ISNULL(ext.cFree6, '') AS cFree6,ISNULL(ext.cFree7, '') AS cFree7,ISNULL(ext.cFree8, '') AS cFree8,ISNULL(ext.cFree9, '') AS cFree9,ISNULL(ext.cFree10, '') AS cFree10 INTO #TempERP FROM ICSWareHouseLotInfoLog a INNER JOIN ICSInventoryLot lot ON a.LotNo=lot.LotNo AND a.WorkPoint=lot.WorkPoint INNER JOIN ICSExtension ext ON lot.ExtensionID=ext.ID AND lot.WorkPoint=ext.WorkPoint INNER JOIN ICSInventory inv ON a.InvCode=inv.InvCode AND a.WorkPoint=inv.WorkPoint LEFT JOIN ICSInventoryBatchEnable invBat ON a.InvCode=invBat.InvCode AND a.ToWarehouseCode=invBat.WHCode AND a.WorkPoint=invBat.WorkPoint INNER JOIN ICSInventoryLotDetail b ON a.LotNo=b.LotNo AND a.WorkPoint=b.WorkPoint INNER JOIN ICSMOApplyNegDetail c ON b.TransCode=c.ApplyNegCode AND b.TransSequence=c.Sequence AND b.WorkPoint=c.WorkPoint INNER JOIN ICSMOIssue m ON c.SourceDetailID=m.IssueDetailID AND c.WorkPoint=m.WorkPoint LEFT JOIN ICSMOPick x ON m.PickID=x.PickID AND m.WorkPoint=x.WorkPoint LEFT JOIN ICSMO y ON x.MODetailID=y.MODetailID AND x.WorkPoint=y.WorkPoint LEFT JOIN ICSMOApply z ON m.ApplyDetailID=z.ApplyDetailID AND m.WorkPoint=z.WorkPoint INNER JOIN ICSConfiguration con ON con.Code='Stock001' AND a.WorkPoint=con.WorkPoint WHERE a.Identification='{0}' AND a.ERPUpload='0' AND ISNULL(a.LogID, '')='' GROUP BY ISNULL(y.DepCode, ''),a.ToWarehouseCode,ISNULL(z.ApplyCode, y.MOCode),a.MUSER,a.InvCode,m.ApplyDetailID, m.PickID,con.Enable ,a.WorkPoint,ISNULL(ext.ProjectCode, ''),CASE WHEN (invBat.BatchEnable IS NULL AND ISNULL(inv.BatchEnable, '0')='1') OR ISNULL(invBat.BatchEnable, '0')='1' THEN ISNULL(ext.BatchCode, '') ELSE '' END,ISNULL(ext.Version, ''),ISNULL(ext.Brand, ''), ISNULL(ext.cFree1, ''),ISNULL(ext.cFree2, ''),ISNULL(ext.cFree3, ''),ISNULL(ext.cFree4, ''),ISNULL(ext.cFree5, ''),ISNULL(ext.cFree6, ''),ISNULL(ext.cFree7, ''),ISNULL(ext.cFree8, ''),ISNULL(ext.cFree9, ''),ISNULL(ext.cFree10, '') UNION ALL SELECT ISNULL(y.DepCode, '')+a.ToWarehouseCode+a.MUSER AS Costre,ISNULL(y.DepCode, '') AS DepCode,a.ToWarehouseCode AS WarehouseCode,CASE WHEN m.ApplyDetailID IS NOT NULL THEN '领料申请单' WHEN m.PickID IS NOT NULL THEN '生产订单' ELSE '' END AS SourceType,ISNULL(z.ApplyCode, y.MOCode) AS MOCode,a.MUSER,ROW_NUMBER() OVER (ORDER BY ISNULL(y.DepCode, ''),a.ToWarehouseCode,ISNULL(z.ApplyCode, y.MOCode),ISNULL(m.ApplyDetailID, m.PickID),a.InvCode) AS Sequence, a.InvCode,SUM(a.Quantity) AS Quantity,0 AS Amount,ISNULL(m.ApplyDetailID, m.PickID) AS SourceDetailID,con.Enable AS UpdateTodoQuantity ,a.WorkPoint,ISNULL(ext.ProjectCode, '') AS ProjectCode,CASE WHEN (invBat.BatchEnable IS NULL AND ISNULL(inv.BatchEnable, '0')='1') OR ISNULL(invBat.BatchEnable, '0')='1' THEN ISNULL(ext.BatchCode, '') ELSE '' END AS BatchCode,ISNULL(ext.Version, '') AS Version,ISNULL(ext.Brand, '') AS Brand, ISNULL(ext.cFree1, '') AS cFree1,ISNULL(ext.cFree2, '') AS cFree2,ISNULL(ext.cFree3, '') AS cFree3,ISNULL(ext.cFree4, '') AS cFree4,ISNULL(ext.cFree5, '') AS cFree5,ISNULL(ext.cFree6, '') AS cFree6,ISNULL(ext.cFree7, '') AS cFree7,ISNULL(ext.cFree8, '') AS cFree8,ISNULL(ext.cFree9, '') AS cFree9,ISNULL(ext.cFree10, '') AS cFree10 FROM ICSWareHouseLotInfoLog a INNER JOIN ICSInventoryLot lot ON a.LotNo=lot.LotNo AND a.WorkPoint=lot.WorkPoint INNER JOIN ICSExtension ext ON lot.ExtensionID=ext.ID AND lot.WorkPoint=ext.WorkPoint INNER JOIN ICSInventory inv ON a.InvCode=inv.InvCode AND a.WorkPoint=inv.WorkPoint LEFT JOIN ICSInventoryBatchEnable invBat ON a.InvCode=invBat.InvCode AND a.ToWarehouseCode=invBat.WHCode AND a.WorkPoint=invBat.WorkPoint INNER JOIN ICSWareHouseLotInfoLog b ON a.LogID=b.ID AND a.WorkPoint=b.WorkPoint INNER JOIN ICSMOIssue m ON b.TransCode=m.IssueCode AND b.TransSequence=m.Sequence AND b.WorkPoint=m.WorkPoint LEFT JOIN ICSMOPick x ON m.PickID=x.PickID AND m.WorkPoint=x.WorkPoint LEFT JOIN ICSMO y ON x.MODetailID=y.MODetailID AND x.WorkPoint=y.WorkPoint LEFT JOIN ICSMOApply z ON m.ApplyDetailID=z.ApplyDetailID AND m.WorkPoint=z.WorkPoint INNER JOIN ICSConfiguration con ON con.Code='Stock001' AND a.WorkPoint=con.WorkPoint WHERE a.Identification='{0}' AND a.ERPUpload='0' AND ISNULL(a.LogID, '')<>'' GROUP BY ISNULL(y.DepCode, ''),a.ToWarehouseCode,ISNULL(z.ApplyCode, y.MOCode),a.MUSER,a.InvCode,m.ApplyDetailID, m.PickID,con.Enable ,a.WorkPoint,ISNULL(ext.ProjectCode, ''),CASE WHEN (invBat.BatchEnable IS NULL AND ISNULL(inv.BatchEnable, '0')='1') OR ISNULL(invBat.BatchEnable, '0')='1' THEN ISNULL(ext.BatchCode, '') ELSE '' END,ISNULL(ext.Version, ''),ISNULL(ext.Brand, ''), ISNULL(ext.cFree1, ''),ISNULL(ext.cFree2, ''),ISNULL(ext.cFree3, ''),ISNULL(ext.cFree4, ''),ISNULL(ext.cFree5, ''),ISNULL(ext.cFree6, ''),ISNULL(ext.cFree7, ''),ISNULL(ext.cFree8, ''),ISNULL(ext.cFree9, ''),ISNULL(ext.cFree10, '') IF EXISTS(SELECT Costre FROM #TempERP WHERE SourceType='{0}') BEGIN RAISERROR('" + language.GetNameByCode("WMSAPIInfo135") + @"',16,1); END SELECT DISTINCT Costre,WorkPoint,DepCode,WarehouseCode AS WHCode,SourceType,MOCode AS SourceCode,MUSER AS [User],SYSDATETIME() AS MTime,UpdateTodoQuantity FROM #TempERP SELECT Costre,Sequence,InvCode,Quantity,Amount,SourceDetailID,ProjectCode,BatchCode,Version,Brand,cFree1,cFree2,cFree3,cFree4,cFree5,cFree6,cFree7,cFree8,cFree9,cFree10 FROM #TempERP DROP TABLE #TempERP"; } else { throw new Exception(language.GetNameByCode("WMSAPIInfo003"));//"类型不符!"); } sql = string.Format(sql, Identification); DataSet ds = DBHelper.SQlReturnDataSet(sql, cmd); string Inputstr = DataToJsonHelper.DataSetToJson(ds, "details", "Costre"); string resultStr = HTTPHelper.HttpPost(TransType, ERPUrl.MOIssueDocNegativeURL, Inputstr); Result result = new Result(); result = JsonConvert.DeserializeObject(resultStr); if (result.Success) { try { JArray res = (JArray)JsonConvert.DeserializeObject(result.Data.ToString()); foreach (var item in res) { JObject jo = (JObject)item; JArray resdetail = (JArray)JsonConvert.DeserializeObject(jo["details"].ToString()); foreach (var detail in resdetail) { JObject det = (JObject)detail; ICSWareHouseLotInfoService.WareHouseLotInfoLogUpdate(TransType, det["SourceDetailID"].ToString(), Identification, jo["ID"].ToString(), det["DetailID"].ToString(), jo["IssueNEGCode"].ToString(), det["Sequence"].ToString(), cmd, language); } } } catch (Exception ex) { log.Debug(ex.ToString()); log.Debug(resultStr); } } else { throw new Exception(language.GetNameByCode("WMSAPIInfo080") + result.Message); } #endregion } catch (Exception) { throw; } } #endregion #region 生产入库 /// /// 生产入库 /// /// /// /// /// /// public static void ManufactureReceiveDoc(string LotNo, string Quantity, string WorkPoint, SqlCommand cmd, Dictionary language) { try { string sql = @"DECLARE @Status VARCHAR(10) SELECT @Status=c.ERPStatus FROM ICSInventoryLot a INNER JOIN ICSInventoryLotDetail b ON a.LotNo=b.LotNo AND a.WorkPoint=b.WorkPoint INNER JOIN ICSMO c ON b.TransCode=c.MOCode AND b.TransSequence=c.Sequence AND b.WorkPoint=c.WorkPoint WHERE a.LotNo='{0}' AND a.WorkPoint='{1}' IF (@Status IS NULL) BEGIN RAISERROR('" + language.GetNameByCode("WMSAPIInfo081") + @"',16,1); RETURN END ELSE IF (@Status='3') BEGIN RAISERROR('" + language.GetNameByCode("WMSAPIInfo082") + @"',16,1); RETURN END UPDATE c SET RCVQuantity=ISNULL(RCVQuantity,0)+'{2}' FROM ICSInventoryLot a INNER JOIN ICSInventoryLotDetail b ON a.LotNo=b.LotNo AND a.WorkPoint=b.WorkPoint INNER JOIN ICSMO c ON b.TransCode=c.MOCode AND b.TransSequence=c.Sequence AND b.WorkPoint=c.WorkPoint WHERE a.LotNo='{0}' AND a.WorkPoint='{1}' IF EXISTS(SELECT a.LotNo FROM ICSInventoryLot a INNER JOIN ICSInventoryLotDetail b ON a.LotNo=b.LotNo AND a.WorkPoint=b.WorkPoint INNER JOIN ICSMO c ON b.TransCode=c.MOCode AND b.TransSequence=c.Sequence AND b.WorkPoint=c.WorkPoint WHERE a.LotNo='{0}' AND a.WorkPoint='{1}' AND c.Quantity /// 生产入库接口 /// /// /// /// public static void ManufactureReceiveDocERP(string TransType, string Identification, SqlCommand cmd, Dictionary language) { try { #region ERP string sql = @"SELECT c.DepCode+a.ToWarehouseCode+c.MOCode+a.MUSER AS Costre,c.MODetailID AS Costre2,c.DepCode,a.ToWarehouseCode AS WarehouseCode,c.MOCode,a.MUSER,ROW_NUMBER() OVER (ORDER BY c.DepCode,a.ToWarehouseCode,c.MOCode,c.MODetailID,a.InvCode) AS Sequence, a.InvCode,SUM(a.Quantity) AS Quantity,SUM(a.Quantity*(lot.Amount/lot.Quantity)) AS Amount,c.MODetailID,con.Enable AS UpdateTodoQuantity ,a.WorkPoint,ISNULL(ext.ProjectCode, '') AS ProjectCode,CASE WHEN (invBat.BatchEnable IS NULL AND ISNULL(inv.BatchEnable, '0')='1') OR ISNULL(invBat.BatchEnable, '0')='1' THEN ISNULL(ext.BatchCode, '') ELSE '' END AS BatchCode,ISNULL(ext.Version, '') AS Version,ISNULL(ext.Brand, '') AS Brand, ISNULL(ext.cFree1, '') AS cFree1,ISNULL(ext.cFree2, '') AS cFree2,ISNULL(ext.cFree3, '') AS cFree3,ISNULL(ext.cFree4, '') AS cFree4,ISNULL(ext.cFree5, '') AS cFree5,ISNULL(ext.cFree6, '') AS cFree6,ISNULL(ext.cFree7, '') AS cFree7,ISNULL(ext.cFree8, '') AS cFree8,ISNULL(ext.cFree9, '') AS cFree9,ISNULL(ext.cFree10, '') AS cFree10,conv.Enable AS CompleteVerification,a.TransSequence INTO #TempERP FROM ICSWareHouseLotInfoLog a INNER JOIN ICSInventoryLot lot ON a.LotNo=lot.LotNo AND a.WorkPoint=lot.WorkPoint INNER JOIN ICSExtension ext ON lot.ExtensionID=ext.ID AND lot.WorkPoint=ext.WorkPoint INNER JOIN ICSInventory inv ON a.InvCode=inv.InvCode AND a.WorkPoint=inv.WorkPoint LEFT JOIN ICSInventoryBatchEnable invBat ON a.InvCode=invBat.InvCode AND a.ToWarehouseCode=invBat.WHCode AND a.WorkPoint=invBat.WorkPoint INNER JOIN ICSInventoryLotDetail b ON a.LotNo=b.LotNo AND a.WorkPoint=b.WorkPoint INNER JOIN ICSMO c ON b.TransCode=c.MOCode AND b.TransSequence=c.Sequence AND b.WorkPoint=c.WorkPoint INNER JOIN ICSConfiguration con ON con.Code='Stock001' AND a.WorkPoint=con.WorkPoint INNER JOIN ICSConfiguration conv ON conv.Code='CompleteVerification' AND a.WorkPoint=conv.WorkPoint WHERE a.Identification='{0}' AND ERPUpload='0' GROUP BY c.DepCode,a.ToWarehouseCode,c.MOCode,a.MUSER,lot.Amount,lot.Quantity,a.InvCode,c.MODetailID,con.Enable,conv.Enable ,a.WorkPoint,ISNULL(ext.ProjectCode, ''),CASE WHEN (invBat.BatchEnable IS NULL AND ISNULL(inv.BatchEnable, '0')='1') OR ISNULL(invBat.BatchEnable, '0')='1' THEN ISNULL(ext.BatchCode, '') ELSE '' END,ISNULL(ext.Version, ''),ISNULL(ext.Brand, ''), ISNULL(ext.cFree1, ''),ISNULL(ext.cFree2, ''),ISNULL(ext.cFree3, ''),ISNULL(ext.cFree4, ''),ISNULL(ext.cFree5, ''),ISNULL(ext.cFree6, ''),ISNULL(ext.cFree7, ''),ISNULL(ext.cFree8, ''),ISNULL(ext.cFree9, ''),ISNULL(ext.cFree10, ''),a.TransSequence SELECT DISTINCT Costre,WorkPoint,DepCode,WarehouseCode AS WHCode,MOCode,MUSER AS [User],SYSDATETIME() AS MTime,UpdateTodoQuantity,CompleteVerification FROM #TempERP SELECT Costre,Costre2,TransSequence,Sequence,InvCode,Quantity,Amount,MODetailID,ProjectCode,BatchCode,Version,Brand,cFree1,cFree2,cFree3,cFree4,cFree5,cFree6,cFree7,cFree8,cFree9,cFree10 FROM #TempERP SELECT c.MODetailID AS Costre2,a.TransCode,a.TransSequence AS Sequence,a.InvCode,a.Quantity,c.Amount,c.PickID,ISNULL(ext.ProjectCode, '') AS ProjectCode,CASE WHEN (invBat.BatchEnable IS NULL AND ISNULL(inv.BatchEnable, '0')='1') OR ISNULL(invBat.BatchEnable, '0')='1' THEN ISNULL(ext.BatchCode, '') ELSE '' END AS BatchCode,ISNULL(ext.Version, '') AS Version,ISNULL(ext.Brand, '') AS Brand,ISNULL(ext.cFree1, '') AS cFree1,ISNULL(ext.cFree2, '') AS cFree2,ISNULL(ext.cFree3, '') AS cFree3,ISNULL(ext.cFree4, '') AS cFree4,ISNULL(ext.cFree5, '') AS cFree5,ISNULL(ext.cFree6, '') AS cFree6,ISNULL(ext.cFree7, '') AS cFree7,ISNULL(ext.cFree8, '') AS cFree8,ISNULL(ext.cFree9, '') AS cFree9,ISNULL(ext.cFree10, '') AS cFree10 FROM ICSWareHouseLotInfoLog a INNER JOIN ICSMO b ON b.MOCode=a.TransCode AND b.WorkPoint=a.WorkPoint INNER JOIN ICSMOPick c ON c.MODetailID=b.MODetailID AND c.WorkPoint=b.WorkPoint AND a.TransSequence=b.Sequence+'~'+c.Sequence INNER JOIN ICSExtension ext ON ext.ID=c.ExtensionID AND ext.WorkPoint=c.WorkPoint INNER JOIN ICSInventory inv ON a.InvCode=inv.InvCode AND a.WorkPoint=inv.WorkPoint LEFT JOIN ICSInventoryBatchEnable invBat ON a.InvCode=invBat.InvCode AND a.ToWarehouseCode=invBat.WHCode AND a.WorkPoint=invBat.WorkPoint WHERE a.Identification='{0}' AND a.TransType='12' DROP TABLE #TempERP"; sql = string.Format(sql, Identification); DataSet ds = DBHelper.SQlReturnDataSet(sql, cmd); string Inputstr = DataToJsonHelper.DataSetToJson(ds, "details", "Costre","detailss", "Costre2"); string resultStr = HTTPHelper.HttpPost(TransType, ERPUrl.ManufactureReceiveDocURL, Inputstr); Result result = new Result(); result = JsonConvert.DeserializeObject(resultStr); if (result.Success) { try { JArray res = (JArray)JsonConvert.DeserializeObject(result.Data.ToString()); foreach (var item in res) { JObject jo = (JObject)item; JArray resdetail = (JArray)JsonConvert.DeserializeObject(jo["details"].ToString()); foreach (var detail in resdetail) { JObject det = (JObject)detail; ICSWareHouseLotInfoService.WareHouseLotInfoLogUpdate(TransType, det["MODetailID"].ToString(), Identification, jo["ID"].ToString(), det["DetailID"].ToString(), jo["MRCVCode"].ToString(), det["Sequence"].ToString(), cmd, language); JArray resdetails = (JArray)JsonConvert.DeserializeObject(det["detailss"].ToString()); foreach (var details in resdetails) { JObject dets = (JObject)details; ICSWareHouseLotInfoService.WareHouseLotInfoLogUpdate(TransType, det["MODetailID"].ToString(), Identification, det["IDSS"].ToString(), dets["DetailID"].ToString(), dets["MRCVCode"].ToString(), dets["Sequence"].ToString(), cmd, language); } } } } catch (Exception ex) { log.Debug(ex.ToString()); log.Debug(resultStr); } } else { throw new Exception(language.GetNameByCode("WMSAPIInfo080") + result.Message); } #endregion } catch (Exception) { throw; } } #endregion #region 开立的生产入库单 /// /// 开立的生产入库单 /// /// /// /// /// /// public static void ManufactureReceive(string LotNo, string Quantity, string WorkPoint, SqlCommand cmd, Dictionary language) { try { string sql = @"DECLARE @Status VARCHAR(10) SELECT @Status=c.Status FROM ICSInventoryLot a INNER JOIN ICSInventoryLotDetail b ON a.LotNo=b.LotNo AND a.WorkPoint=b.WorkPoint INNER JOIN ICSManufactureReceive c ON b.TransCode=c.RCVCode AND b.TransSequence=c.Sequence AND b.WorkPoint=c.WorkPoint WHERE a.LotNo='{0}' AND a.WorkPoint='{1}' AND c.Type='1' IF (@Status IS NULL) BEGIN RAISERROR('" + language.GetNameByCode("WMSAPIInfo081") + @"',16,1); RETURN END ELSE IF (@Status!='1') BEGIN RAISERROR('" + language.GetNameByCode("WMSAPIInfo137") + @"',16,1); RETURN END UPDATE c SET RCVQuantity=ISNULL(RCVQuantity,0)+'{2}' FROM ICSInventoryLot a INNER JOIN ICSInventoryLotDetail b ON a.LotNo=b.LotNo AND a.WorkPoint=b.WorkPoint INNER JOIN ICSManufactureReceive c ON b.TransCode=c.RCVCode AND b.TransSequence=c.Sequence AND b.WorkPoint=c.WorkPoint WHERE a.LotNo='{0}' AND a.WorkPoint='{1}' AND c.Type='1' IF EXISTS(SELECT a.LotNo FROM ICSInventoryLot a INNER JOIN ICSInventoryLotDetail b ON a.LotNo=b.LotNo AND a.WorkPoint=b.WorkPoint INNER JOIN ICSManufactureReceive c ON b.TransCode=c.RCVCode AND b.TransSequence=c.Sequence AND b.WorkPoint=c.WorkPoint WHERE a.LotNo='{0}' AND a.WorkPoint='{1}' AND c.Type='1' AND c.Quantity /// 开立的生产入库单 /// /// /// /// public static void ManufactureReceiveERP(string TransType, string Identification, SqlCommand cmd, Dictionary language) { try { #region ERP开立状态单据审核 string sql = @"IF EXISTS(SELECT b.ID FROM ICSManufactureReceive b WHERE b.RCVCode+b.WorkPoint IN (SELECT a.TransCode+a.WorkPoint FROM ICSWareHouseLotInfoLog a WHERE a.Identification='{0}') AND b.Quantity!=b.RCVQuantity) BEGIN RAISERROR('" + language.GetNameByCode("WMSAPIInfo096") + @"',16,1); RETURN END SELECT b.RCVID AS ID,a.MUSER AS [User],SYSDATETIME() AS MTime,con.Enable AS UpdateTodoQuantity,conStock.Enable AS UpdateStock,a.WorkPoint FROM ICSWareHouseLotInfoLog a INNER JOIN ICSManufactureReceive b ON a.TransCode=b.RCVCode AND a.TransSequence=b.Sequence AND a.WorkPoint=b.WorkPoint INNER JOIN ICSConfiguration con ON con.Code='Stock001' AND a.WorkPoint=con.WorkPoint INNER JOIN ICSConfiguration conStock ON conStock.Code='UpdateStock004' AND a.WorkPoint=conStock.WorkPoint WHERE a.Identification='{0}' AND ERPUpload='0' GROUP BY b.RCVID,a.MUSER,con.Enable,conStock.Enable,a.WorkPoint"; sql = string.Format(sql, Identification); DataTable dt = DBHelper.SQlReturnData(sql, cmd); string Inputstr = JsonConvert.SerializeObject(dt); string resultStr = HTTPHelper.HttpPost(TransType, ERPUrl.ICSManufactureReceiveURL, Inputstr); Result result = new Result(); result = JsonConvert.DeserializeObject(resultStr); if (result.Success) { try { foreach (DataRow dr in dt.Rows) { ICSWareHouseLotInfoService.WareHouseLotInfoLogUpdate(TransType, dr["ID"].ToString(), Identification, "", "", "", "", cmd, language); } } catch (Exception ex) { log.Debug(ex.ToString()); log.Debug(resultStr); } } else { throw new Exception(language.GetNameByCode("WMSAPIInfo080") + result.Message); } #endregion } catch (Exception) { throw; } } #endregion #region 返工工单 /// /// 返工工单 /// /// /// /// /// /// public static void ReWorkReceiveMo(string LotNo, string Quantity, string WarehouseCode, string LocationCode, string WorkPoint, String User, string BusinessCode, SqlCommand cmd, Dictionary language) { try { string sql = @"DECLARE @Status VARCHAR(10) SELECT @Status=c.ERPStatus FROM ICSInventoryLot a INNER JOIN ICSInventoryLotDetail b ON a.LotNo=b.LotNo AND a.WorkPoint=b.WorkPoint INNER JOIN ICSMO c ON b.TransCode=c.MOCode AND b.WorkPoint=c.WorkPoint INNER JOIN ICSMOPick d ON d.MODetailID=c.MODetailID AND b.WorkPoint=c.WorkPoint and b.TransSequence=c.Sequence+'-'+d.Sequence WHERE a.LotNo='{0}' AND a.WorkPoint='{1}' IF (@Status IS NULL) BEGIN RAISERROR('" + language.GetNameByCode("WMSAPIInfo081") + @"',16,1); RETURN END ELSE IF (@Status='3') BEGIN RAISERROR('" + language.GetNameByCode("WMSAPIInfo082") + @"',16,1); RETURN END UPDATE d SET IssueQuantity=ISNULL(IssueQuantity,0)+'{2}' FROM ICSInventoryLot a INNER JOIN ICSInventoryLotDetail b ON a.LotNo=b.LotNo AND a.WorkPoint=b.WorkPoint INNER JOIN ICSMO c ON b.TransCode=c.MOCode AND b.WorkPoint=c.WorkPoint INNER JOIN ICSMOPick d ON d.MODetailID=c.MODetailID AND d.WorkPoint=c.WorkPoint and b.TransSequence=c.Sequence+'-'+d.Sequence WHERE a.LotNo='{0}' AND a.WorkPoint='{1}' IF EXISTS(SELECT a.LotNo FROM ICSInventoryLot a INNER JOIN ICSInventoryLotDetail b ON a.LotNo=b.LotNo AND a.WorkPoint=b.WorkPoint INNER JOIN ICSMO c ON b.TransCode=c.MOCode AND b.WorkPoint=c.WorkPoint INNER JOIN ICSMOPick d ON d.MODetailID=c.MODetailID AND d.WorkPoint=c.WorkPoint and b.TransSequence=c.Sequence+'-'+d.Sequence WHERE a.LotNo='{0}' AND a.WorkPoint='{1}' AND d.IssueQuantity>d.Quantity) BEGIN RAISERROR('" + language.GetNameByCode("WMSAPIInfo083") + @"',16,1); END"; sql = string.Format(sql, LotNo, WorkPoint, Quantity); if (!DBHelper.ExecuteNonQuery(sql, cmd)) { throw new Exception(language.GetNameByCode("WMSAPIInfo366"));//"生产工单更新失败!"); } } catch (Exception) { throw; } } /// /// 返工工单 /// /// /// /// public static void ReWorkReceiveMoERP(string TransType, string Identification, SqlCommand cmd, Dictionary language) { try { #region ERP开立状态单据审核 String sql = @"SELECT c.DepCode+a.ToWarehouseCode+c.MOCode+a.MUSER AS Costre,c.DepCode,a.ToWarehouseCode AS WarehouseCode,c.MOCode,a.MUSER,d.Sequence AS Sequence, a.InvCode,SUM(a.Quantity) AS Quantity,0 AS Amount,d.PickID AS MODetailID,Enable AS UpdateTodoQuantity ,a.WorkPoint,ISNULL(ext.ProjectCode, '') AS ProjectCode,CASE WHEN (invBat.BatchEnable IS NULL AND ISNULL(inv.BatchEnable, '0')='1') OR ISNULL(invBat.BatchEnable, '0')='1' THEN ISNULL(ext.BatchCode, '') ELSE '' END AS BatchCode,ISNULL(ext.Version, '') AS Version,ISNULL(ext.Brand, '') AS Brand, ISNULL(ext.cFree1, '') AS cFree1,ISNULL(ext.cFree2, '') AS cFree2,ISNULL(ext.cFree3, '') AS cFree3,ISNULL(ext.cFree4, '') AS cFree4,ISNULL(ext.cFree5, '') AS cFree5,ISNULL(ext.cFree6, '') AS cFree6,ISNULL(ext.cFree7, '') AS cFree7,ISNULL(ext.cFree8, '') AS cFree8,ISNULL(ext.cFree9, '') AS cFree9,ISNULL(ext.cFree10, '') AS cFree10 INTO #TempERP FROM ICSWareHouseLotInfoLog a INNER JOIN ICSInventoryLot lot ON a.LotNo=lot.LotNo AND a.WorkPoint=lot.WorkPoint INNER JOIN ICSExtension ext ON lot.ExtensionID=ext.ID AND lot.WorkPoint=ext.WorkPoint INNER JOIN ICSInventory inv ON a.InvCode=inv.InvCode AND a.WorkPoint=inv.WorkPoint LEFT JOIN ICSInventoryBatchEnable invBat ON a.InvCode=invBat.InvCode AND a.ToWarehouseCode=invBat.WHCode AND a.WorkPoint=invBat.WorkPoint INNER JOIN ICSInventoryLotDetail b ON a.LotNo=b.LotNo AND a.WorkPoint=b.WorkPoint INNER JOIN ICSMO c ON b.TransCode=c.MOCode AND b.WorkPoint=c.WorkPoint INNER JOIN ICSMOPick d ON d.MODetailID=c.MODetailID AND d.WorkPoint=c.WorkPoint and b.TransSequence=c.Sequence+'-'+d.Sequence INNER JOIN ICSConfiguration con ON con.Code='Stock001' AND a.WorkPoint=con.WorkPoint WHERE a.Identification='{0}' AND ERPUpload='0' GROUP BY c.DepCode,a.ToWarehouseCode,c.MOCode,a.MUSER,a.InvCode,d.PickID,Enable,d.Sequence ,a.WorkPoint,ISNULL(ext.ProjectCode, ''),CASE WHEN (invBat.BatchEnable IS NULL AND ISNULL(inv.BatchEnable, '0')='1') OR ISNULL(invBat.BatchEnable, '0')='1' THEN ISNULL(ext.BatchCode, '') ELSE '' END,ISNULL(ext.Version, ''),ISNULL(ext.Brand, ''), ISNULL(ext.cFree1, ''),ISNULL(ext.cFree2, ''),ISNULL(ext.cFree3, ''),ISNULL(ext.cFree4, ''),ISNULL(ext.cFree5, ''),ISNULL(ext.cFree6, ''),ISNULL(ext.cFree7, ''),ISNULL(ext.cFree8, ''),ISNULL(ext.cFree9, ''),ISNULL(ext.cFree10, '') SELECT DISTINCT Costre,WorkPoint,DepCode,WarehouseCode AS WHCode,MOCode,MUSER AS [User],SYSDATETIME() AS MTime,UpdateTodoQuantity FROM #TempERP SELECT Costre,Sequence,InvCode,Quantity,Amount,MODetailID,ProjectCode,BatchCode,Version,Brand,cFree1,cFree2,cFree3,cFree4,cFree5,cFree6,cFree7,cFree8,cFree9,cFree10 FROM #TempERP DROP TABLE #TempERP"; sql = string.Format(sql, Identification); DataSet ds = DBHelper.SQlReturnDataSet(sql, cmd); string Inputstr = DataToJsonHelper.DataSetToJson(ds, "details", "Costre"); string resultStr = HTTPHelper.HttpPost(TransType, ERPUrl.ICSReWorkReceiveMoURL, Inputstr); Result result = new Result(); result = JsonConvert.DeserializeObject(resultStr); if (result.Success) { try { JArray res = (JArray)JsonConvert.DeserializeObject(result.Data.ToString()); foreach (var item in res) { JObject jo = (JObject)item; JArray resdetail = (JArray)JsonConvert.DeserializeObject(jo["details"].ToString()); foreach (var detail in resdetail) { JObject det = (JObject)detail; ICSWareHouseLotInfoService.WareHouseLotInfoLogUpdate(TransType, det["MODetailID"].ToString(), Identification, jo["ID"].ToString(), det["DetailID"].ToString(), jo["MRCVCode"].ToString(), det["Sequence"].ToString(), cmd, language); } } } catch (Exception ex) { log.Debug(ex.ToString()); log.Debug(resultStr); } } else { throw new Exception(language.GetNameByCode("WMSAPIInfo080") + result.Message); } #endregion } catch (Exception) { throw; } } #endregion } }